ILX LIGHTWAVE OMH-6722B CALIBRATION and ILX LIGHTWAVE OMH-6722B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE OMH-6722B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Sensor?
Shop for Comparable Products on our
 used Optical Power Sensor page or new Optical Power Sensor page

 
   ILX LIGHTWAVE OMH-6722B   Description / Specification:    
ILX LIGHTWAVE OMH-6722B 400 to 1100 nm Silicon Optical Power/Wavelength Head

The ILX OMH-6722B Optical Power and Wavelength Measurement Head provides flexibility to easily and accurately measure the optical power and wavelength of laser sources from the blue to the near infrared spectrum. These products incorporate ILX’s unique integrating sphere-based power and wavelength measurement capability. The OMH-6722B power/wavehead provides accurate power and wavelength measurement from 400 to 1100 nm. ILX OMH-6722B integrating sphere simplifies optical power measurements of laser diodes and LEDs by eliminating measurement problems related to detector saturation, alignment beam profile, polarization, and back reflection. Integrating spheres are inherently insensitive to beam profiles, providing you with more flexibility in laser type and launch conditions.
Specifications.

Wavelength Range: 400 to 1100 nm.
Accuracy: ±1.0 nm.
Detection (minimum power required): -20 dBm.
Temperature Coefficient: <-0.03nm/°C (typical).
Power Range: -40 to +30 dBm.
Damage Threshold: +42 dBm.
Accuracy: ±3.5%.
Sensor Type: Silicon.
Noise: 5 nW p-p (typical) at 980 nm.
Linearity Temperature Coefficient: 0.1% /°C (typical).



 



Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your ILX LIGHTWAVE OMH-6722B CALIBRATION and/or ILX LIGHTWAVE OMH-6722B 400 to 1100 nm Silicon Optical Power/Wavelength Head REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: